Contact: +86 13816343976  
  User Login

MemberID:   
PassWord:   

   

  Consulting
  
  Search
KeyWord: 
Classification:  
  Categories
Electronic/electroplating...
X ray fluorescence spectr...
Thickness Tester...
The RoHS tester...
Portable thickness measur...
Portable thickness gauge ...
Portable thickness gauge ...
Portable thickness gauge ...
Portable thickness gauge ...
Electrolytic thickness ga...
Water treatment apparatus...
Acidity / ISE thermometer...
Pen type pH meter...
Portable acidity meter...
Table join type pH meter...
Multi function meter...
Conductivity / TDS / sali...
Pen type conductivity met...
Portable electric conduct...
Conductivity meter...
Multi function electric c...
Dissolved oxygen meter...
Portable dissolved oxygen...
Lab dissolved oxygen inst...
Multifunctional dissolved...
Multi parameter measuring...
UTW990 series multi param...
Economical and practical ...
Multi parameter measuring...
Microcomputer ion concent...
Photometer...
Portable photometer...
Portable multi parameter ...
Microcomputer ion concent...
COD / BOD measuring instr...
COD multi parameter measu...
The COD micro digestion h...
Microcomputer BOD measuri...
High performance multipur...
High performance multipur...
Optional accessories...
PH electrode...
Ion electrode...
Electrode conductance...
Dissolved oxygen electrod...
Magnetic stirrer...
Oil meter...
 Products   .
 
ProductName:UTX650X ray fluorescence spectrometer
ProductNO.:
Price:无
AddTime:2011-4-18 15:02:31
Order:

Product Name: UTX650X ray fluorescence spectrometer

Order number:

Optional accessories: no

Inquiry:

Detailed description

One, product introduction

UTX650 is an economy, practical, easy to operate by X ray fluorescence spectrometer, suitable for:

Hardware, connectors, electrical connector plating, plating, plastics, PCB, ABS magnesium alloy electroplating; content of ordinary alloy analysis. Plating bath analysis.

Coating thickness measurement

Hardware, connectors, electrical connector plating Au, Ag, Sn, Ni, Cu, Zn, Cr, NiP, SnPb, SnCu, ZnNi, AuPdNi such as alloy;

PCB Au, Ag Cu, electroplating, Ni, NiP, SnPb alloy

Plastic, ABS, magnesium alloy electroplating Au, Ag, Sn, Ni, Cu, Zn, Cr, NiP etc.

Alloy analysis

Stainless steel in Fe, Cr, Ni, Mo and other components

Brass Cu, Zn, Pb and other components

Copper in Cu, Zn, Sn, Pb and other components

Solder in the Sn, Pb and other ingredients

Plating bath analysis

Electroplating solution of Au, Ag, Cu, Ni, Cr, Zn, Sn concentration of main salt

Two, product characteristics

1, from K to U rapid element analysis, metal plating thickness detection

2, the detection sensitivity 0.01% to 100%; 0.02um to 40um coating

3, short measuring time, each measuring only 10-60 seconds

4, 15-20 times CCD color system was used for sample image observation

5, in a variety of shapes and specifications of the collimator can be chosen

6, a large window proportional counter, improve the stability of measurement

7, machinery and has the advantages of simple structure, reliable

8, FP basic algorithm software

9, the flexible application of analysis software

10, simple installation, fast instrument

Three, technical indicators

1, the implementation of product standards: DIN50987, ISO3497, ASTN.D568

2, the product parameters:

Measuring principle

Energy dispersive X ray fluorescence analysis

Determination of object

Solid, liquid, powder

Measuring function

Single plating, alloy coating, coating thickness, most can be measured 5 layer;

Elemental analysis ( material component analysis )

Plating bath analysis ( electroplating syrup main salt components analysis )

Measurement limit

Coating thickness: 0.02um, elemental analysis: 100ppm

Thickness measurement range

0.02-40 um,(W、Au、Pb)10μm、(Cu、Zn、Ni、Cr、Sn)40um,

Thickness measurement error

The first layer is less than±5%,The second layer is less than±10%,The third layer is less than±15%

Element analysis of measuring range

Measuring element K19-U92

Test time

Thickness measurement:10-60s,Element analysis:10-60s

X ray generator part

X light tube of origin and brand

The United States of America (OXFORD)

X ray tube target

W target, Rh, Mo, Ag, Cr target optional

X ray tube window

Be

Electrical parameters

50W、4-50kV,0-1000uA

Cooling mode

Silicone grease cooling

X ray irradiation

↓X ray from top to bottom

Radiation area

Minimum spotφ0.1mm

Service life

15000-20000h

Detector

Detector of origin and brand

The United States of America(LND)

Cooling mode

Electric refrigeration (-1900C)

Resolution

The Mn half peak width 760eV

The detection window

Be、Window area:400mm2

High-voltage power supply

High voltage package of origin and brand

The United States of America (SPELLMAN)

Input voltage

24VDC±10%、

Output voltage

0-50kV、0-2.0mA,Output precision 0.01%

Remarks

Software automatic detection function

Light path system

Collimator system

Single collimatorφ0.1mm、

Focusing system

Laser focus

Filter

Multiple filter (Ni、Cu、Mo、Al、Ti)

Sample observation system

The 3000000 pixel high-definition CCD camera, 20 times optical zoom.

Sample room

Sample room interior space(mm)

(W x H x D):450×160×400mm

Sample size

(WxD):250×275mm

Sample table bearing weight

≤5kg

The test sample size

W x H x D:440×150×390mm。

Sample table control

Manual sample stage

Work bench mobile technology data

X=200±5、Y=200±5、Z=160±5mm

A data processing system

Control computer

Lenovo brand M7150, 1G memory, 160G hard disk

Monitor

Lenovo 17 inch LCD Monitor

Report results

Word, PDF format

Software

Operating system:WindowsXP、OEM simplified Chinese Edition

Coating thickness measurement software, element analysis software

Software language

Simplified Chinese, traditional Chinese, English, other

Apparatus for packaging parameters

The main body of the device size(mm)

W580×H600×D715mm

Body weight

About 60kg

The environment of the use

Working environment

Temperature 15-250C,Humidity  40-70%RH

Power supply system

Single-phase  220V±10%,Working voltage in allowed range

Other

1.      Don’t close to generate strong magnetic field, electric field, high frequency device

2.     Reducing vibration

3.      Less dust, low humidity, no corrosive gas

4.      No direct sunlight

5.      As the earthquake countermeasures, to consider the fixed device

Previous:No Product   Next:Microwave cavity thickness gauge UTX660
【Refresh】【Collection】【Print】 【Close Window】
 
沪ICP备06036744号