One, application field
UTX650B is an economy, practical, easy to operate by X ray fluorescence spectrometer, suitable for:
Hardware, connectors, electrical connector plating, plating, plastics, PCB, ABS magnesium alloy electroplating; content of ordinary alloy analysis. Plating bath analysis.
Coating thickness measurement
Hardware, connectors, electrical connector plating Au, Ag, Sn, Ni, Cu, Zn, Cr, NiP, SnPb, SnCu, ZnNi, AuPdNi such as alloy;
PCB Au, Ag Cu, electroplating, Ni, NiP, SnPb alloy
Plastic, ABS, magnesium alloy electroplating Au, Ag, Sn, Ni, Cu, Zn, Cr, NiP etc.
Alloy analysis
Stainless steel in Fe, Cr, Ni, Mo and other components
Brass Cu, Zn, Pb and other components
Copper in Cu, Zn, Sn, Pb and other components
Solder in the Sn, Pb and other ingredients
Plating bath analysis
Electroplating solution of Au, Ag, Cu, Ni, Cr, Zn, Sn concentration of main salt
Two, product characteristics
1, from K to U rapid element analysis, metal plating thickness detection
2, the detection sensitivity 0.01% to 100%; 0.02um to 40um coating
3, short measuring time, each measuring only 10-60 seconds
4, 15-20 times CCD color system was used for sample image observation
5, in a variety of shapes and specifications of the collimator can be chosen
6, a large window proportional counter, improve the stability of measurement
7, machinery and has the advantages of simple structure, reliable
8, FP basic algorithm software
9, the flexible application of analysis software
10, simple installation, fast instrument
Three, technical indicators
High-voltage power supply |
Input voltage |
24VDC±10% |
Output voltage |
0-50kV |
Output current |
0-2.0mA |
Output precision |
0.01% |
Remarks |
Software automatic detection function |
X ray tube |
X ray tube target |
W target, Rh, Mo, Ag, Cr target optional |
X ray tube window |
Be |
Electrical parameters |
50W、4-50kV,0-1000uA |
Cooling mode |
Silicone grease cooling |
Service life |
15000-20000h |
Detector |
Detection range |
K19-U92 |
Resolution |
FWHM<760eV |
The detection window |
Be,Window area:400mm2 |
Spectral processing system |
Processor type |
Full digital 32-bit3 DSP |
The number of spectral channels |
256,512,1024,2048 choice |
Counting rate |
More than 100000cps |
Energy range |
1400eV-40960eV |
Dead time |
<3% |
Light path system and sample observation |
Collimator system |
Φ0.11mm |
Focusing system |
Laser focus |
Filter |
Multiple filter (Ni、Cu、Mo、Al、Ti) |
Sample observation system |
The 3000000 pixel high-definition CCD camera, 20 times optical zoom. |
Sample room |
Sample room interior space(mm) |
(W x H x D):450×160×400mm |
Sample size |
(宽×深):250×275mm |
Sample table bearing weight |
≤5kg |
The test sample size |
W x H x D:440×150×390mm。 |
Sample table control |
Simple manual sample stage |
Work bench mobile |
X=200±5、Y=200±5、Z=160±5mm |
Worktable moving precision |
0.02mm |
Computer and software |
Control computer |
Lenovo brand T4900V, 512MB memory, 80G hard disk |
Monitor |
Lenovo 17 inch LCD Monitor |
Operating system |
WindowsXP、OEM simplified Chinese Edition |
Report results |
Word、Excel format |
Software |
Coating thickness measurement software, element analysis software |
Types of software |
FP Fundamental parameter method in software |
Software language |
simplified Chinese, traditional Chinese, English, other |
Spectrum display |
Automatic peak qualitative, KLM markers, spectral overlapping comparison |
Spectral processing |
Total intensity, net intensity, background intensity; the whole area, net area, much element fitting, Gauss fitting; reciprocal spectrum |
Data analysis |
The basic parameters, basic pattern, without standard sample test, peak position correction, substrate amendment |
Weight and size |
The main body of the device size(mm) |
W 580×H 600×D 715mm |
Body weight |
About 60kg |
The environment of the use |
Working environment |
Temperature 15-250C,Humidity 40-70%RH |
Power supply system |
Single-phase 220V±10%,Working voltage in allowed range |
Other |
1. Don’t close to generate strong magnetic field, electric field, high frequency device
2. Reducing vibration
3. Less dust, low humidity, no corrosive gas
4. No direct sunlight
5. As the earthquake countermeasures, to consider the fixed device |
|