Product Name: parameter PH / ion / ORP tester UTW600
Order number: 50201001
Optionalaccessories:10401001,10401002,10401003,10401004,10401005,10401006,10401007,10401008,10401009,10401011,10401012,10401013
Inquiry:
Detailed description
The UTW600 parameter
PH measurement range: - 2 ~ 16.000pH;
PH measurement accuracy: ±0.002pH;
MV / ORP measuring range: 0 ~± 1999.9mV;
MV / ORP measurement accuracy: ± 0.2mV;
PX measuring range: 0 ~ 14.000pX
PX measurement accuracy: ±0.002 pX;
Ion concentration measuring range: 0 ~ 19999ppm;
Ion concentration measurement precision: ±0.5%, An ion; ±1%, ionic, The two dielectric ion;
Temperature measuring range: 0~100℃,32~212oF;
Temperature measurement precision: ±0.3℃,±0.5 oF;
Temperature compensation range: 0~100℃,32~212 oF, automatic or manual;
PH calibration points: 2 point;
The use of calibration solution: NIST ( pH 4 / 6.86 / 9.18 ) or USA ( pH4.01 / 7 / 10.01);
PX calibration points: 2 ~ 5, 10-2 ( 2pX ), 10-3 ( 3pX ), 10-4 ( 4pX ), 10-4 ( 4pX ), 10-5 ( 5pX ), 10-6 ( 6pX ) mol / L;
The built-in ion concentration mode: 13, Na+,Ag+,K+,NH3+,CL-,F-,Ca2+,No3-,Pb2+,I-,Cu2+,Br-,CN-
Data storage: 99 groups;
Communication output: USB standard;
Display: 6 inch LCD screen, having an operation mode icon and message;
Source type: 9V / 350mA power adapter, using 220V / 50Hz;
Dimensions: 210 ( L ) x 188 ( W ) x 60 ( H ) mm;
The weight of the instrument: 1.7kg
The UTW600 function is introduced
UTW600 is a high precision water quality tester, built in 13 concentration of the measuring ion model with pH and redox potential value ( ORP ) measuring function.
Its features are:
1,Multi point automatic calibration;
2,Can automatically identify the standard buffer solution;
3,Automatic electrode slope and state display;
4,The optional pH standard buffer solution: instrument built in NIST / USA two pH standard buffer solution group, you can according to the national standard to choose among a group of calibration apparatus;
5,With automatic temperature compensation function;
6,Multi mode ion measurement;
7,Measurement of relative mV ( R.mV ) function: the ORP model has relative mV measurement function, the use of redox potential calibration solution, you can easily modify the measurement error in order to improve the measurement precision of apparatus for ORP
8,Automatic information prompting function;
9,Data can be stored and output, instrument with 99 groups of data storage function, through USB data line, put the data to the computer
10,Waterproof keyboard and an electrode frame: instrument assembly waterproof panel, Naisuan Jian, you don’t have to worry about the sample on the instrument and damage to equipment, flexible electrode holder that is stopped, the use is very convenient |